Prognostic Factors and Long-Term Outcomes Following Transvaginal Partially Absorbable Minimesh Repair for Pelvic Organ Prolapse

Gold R1, Baruch Y1, Groutz A1

Research Type

Clinical

Abstract Category

Pelvic Organ Prolapse

Gold Pass video coming soon
Find out more

Abstract 100
POP, Incontinence and Imaging
Scientific Podium Short Oral Session 12
Thursday 8th October 2026
09:22 - 09:30
Parallel Hall 3
0.4 Brussels / 0.5 Paris
Capacity: 356
Grafts: Synthetic Pelvic Organ Prolapse Surgery Female
1. Urogynecology Unit, Lis Women’s Hospital, Tel Aviv Medical Center, Tel Aviv University, Tel Aviv, Israel
Presenter
Links

Abstract

Hypothesis / aims of study
To evaluate the long-term safety, efficacy, patient satisfaction, and prognostic factors of transvaginal partially absorbable minimesh (SERATOM®) for pelvic organ prolapse (POP) repair with up to 10-year follow-up.
Study design, materials and methods
Retrospective cohort study of 274 women (from 300 consecutive; 26 excluded for missing data) who underwent SERATOM® minimesh repair for Stage ≥II POP (July 2013–February 2015). Preoperative demographics, POP-Q measurements, and symptoms were recorded. Short-term (4-month POP-Q) and long-term (mean 9.8±0.2 years) follow-up assessed anatomical outcomes, symptom resolution, mesh complications, reoperations, and satisfaction. McNemar tests compared pre- versus long-term symptoms. Multivariate logistic regression identified independent prognostic factors.
Results
Mean age was 62.1±9.6 years; 63.5% had multi-compartment prolapse. Mean operative time was 29.5±7.1 minutes. Short-term anatomical success was 95.2% (259/272). All POP-Q points improved significantly (all P<0.001). No mesh erosions occurred at 10-year follow-up. SUI decreased from 40.4% to 4.8% (P<0.001); OAB from 33.1% to 7.4% (P<0.001); defecation disorders from 8.8% to 1.5% (P<0.001). POP-specific reoperation occurred in 9.1%, independently predicted by prior pelvic surgery (OR 2.63, P=0.045) and posterior mesh placement (OR 2.44, P=0.038). Long-term dyspareunia (5.5%) was predicted by prior hysterectomy (OR 6.33, P=0.005) and preoperative dyspareunia (OR 5.64, P=0.010). Satisfaction was 89.0%±17.6%.
Interpretation of results
Short-term anatomical success at 4 months was 95.2% (259/272). All POP-Q measurement points improved significantly, and analyses demonstrated significant long-term symptom resolution. On multivariate logistic regression, prior pelvic surgery (OR 2.63, 95% CI 1.02–6.76; P=0.045) and posterior mesh placement (OR 2.44, 95% CI 1.05–5.67; P=0.038) independently predicted POP-specific reoperation. Multi-compartment prolapse independently predicted high satisfaction. Prior pelvic surgery was inversely associated with multi-compartment prolapse (OR 0.35, 95% CI 0.18-0.67; P=0.002),
Concluding message
SERATOM® minimesh demonstrated excellent long-term safety with zero mesh erosions at 10 years, high anatomical success, significant and durable symptom resolution, and sustained patient satisfaction. Prior pelvic surgery and posterior placement predict reoperation; prior hysterectomy and preoperative dyspareunia predict long-term dyspareunia. These findings support SERATOM® as a safe transvaginal option for significant POP repair.
Figure 1 Table 1. Patient demographic and preoperative characteristics
Figure 2 . Multivariate logistic regression: independent prognostic factors
Disclosures
Funding none Clinical Trial No Subjects Human Ethics Committee Assuta Medical Center approved the study protocol (ASMC 0020-24). Helsinki Yes Informed Consent No AI Not at all
Citation

Continence 19S (2026) 102577
DOI: 10.1016/j.cont.2026.102577

21/10/2026 22:39:37