Robot-assisted bladder neck artificial urinary sphincter implantation in male patients with neurogenic stress urinary incontinence : a multicenter study

Encatassamy F1, Hascoët J2, Brierre T3, Manunta A2, Le Normand L1, Gamé X3, Peyronnet B2, Perrouin-Verbe M1

Research Type

Clinical

Abstract Category

Male Lower Urinary Tract Symptoms (LUTS) / Voiding Dysfunction

Abstract 678
Urology - Best of the Rest
Scientific Podium Short Oral Session 32
Friday 6th September 2019
15:15 - 15:22
Hall H2
Stress Urinary Incontinence Spinal Cord Injury Surgery Neuropathies: Central Detrusor Overactivity
1.CHU de Nantes, 2.CHU de Rennes, 3.CHU de Toulouse
Presenter
Links

Abstract

Hypothesis / aims of study
The artificial urinary sphincter is currently the gold standard for the treatment of neurogenic stress urinary incontinence due to intrinsic sphincter deficiency. An expert consensus propose a bladder neck cuff implantation. Actually, in this particular population, a bladder neck cuff is interesting owing to : the use of self intermittent catheterization, the pressure applied to bulbar urethra in wheelchair-bound patients, open bladder neck with urine-filled prostatic urethra and the increased risk of infection with a bulbar cuff and frequent endoscopic procedures.
Moreover, a recent multicenter study has suggested that a bladder neck insertion of the artificial urinary sphincter cuff in male patients with neurogenic stress urinary incontinence (SUI) may increase device survival as compared to the standard bulbar urethra cuff placement (1). 
The robot-assisted approach has recently been described to try to minimize the technical complexity and surgical morbidity of bladder neck artificial urinary sphincter implantation (2). The aim of the present study was to report the peri-operative and short term functional outcomes of robot-assisted AUS implantation in male patients with neurogenic SUI due to intrinsic sphincter deficiency.
Study design, materials and methods
All male patients (> 18 years) who underwent a robot-assisted bladder neck artificial urinary sphincter implantation for neurogenic SUI at 3 university hospitals between 2010 and 2018 were included in a retrospective study. Over the study period, the robot-assisted approach was the only surgical approach used for bladder neck artificial urinary sphincter implantation and all devices were implanted at the bladder neck. 
We report revision and explantation rates and short-term functional outcomes. Patients who did not use pads were defined as completely continent. They were defined as socially continent if they use 0 to 1 pad per day.
Results
Twelve patients were included : 4 with spina bifida, 6 with spinal cord injury, two with a cauda equina syndrome. Mean age at the procedure was 37 years. Among them, 80% used self-intermittent catheterization as a voiding method. 

Ten artificial urinary sphincters were implanted around the bladder neck with a robotic approach. Cuff size ranged from 8 to 10. 
Two patients underwent a concomitant augmentation cystoplasty during the same operative time. We required one conversion to bulbar urethra implantation because of major abdominal adherences and one conversion to an open approach of the bladder neck cuff insertion owing a poor tolerance of pneumoperitoneum. These 2 patients were excluded of functional outcomes analysis. 

The median lenght of stay was 4 days (3-8). The median post-operative catheterization duration was 6 days (1-28). The devices were activated in a mean time of 48 days (35-85) after implantation.

Mean follow-up was 200 days. Two explantations were needed in a mean-time of 31 days : one for an early device infection concerning a patient who underwent a concomitant augmentation cystoplasty and one for an erosion of the cuff. 
One revision was performed one year after the implantation for a downsizing of the cuff. 

At the last follow up, 8 patients still had their device in place (80%). Among them, 4 were completely continent (50%) and 3 had a social continence (38%). One patient did not recover his continence.
Interpretation of results
In this present study, we report the excellent functional outcomes of this technique : the global continence rate was 88% (50% of complete continence and 38% with a social continence). 

However, our findings differ from the only preliminary series published to date (2) regarding the surgical morbidity and device outcomes.
This could be due to the smaller experience of our surgeons when compared to the aforementioned study. Actually, 4 of the 5 surgeons involved had a very little robotic experience (less than 50 robotic procedures). The concomitant augmentation cystoplasties can also explain these different outcomes. Indeed, one patient with a concomitant augmentation cystoplasty had an early infection of the device 2 days after the implantation, and needed an explantation of the artificial urinary sphincter. Previously, it had been shown that simultaneous augmentation cystoplasty  lead to an initial increase in articial sphincter infection, but this difference seemed to disappear 3 years after the device insertion (3). Further studies are needed to assess  the infection rate in a longer follow-up.
Concluding message
The robot-assisted bladder neck artificial urinary sphincter implantation has excellent short term functional outcomes in male patients with neurogenic stress urinary incontinence due to intrinsic sphincter deficiency. 
Further studies are needed to assess the long-term outcomes after the learning curve has been overcome.
References
  1. Artificial Urinary Sphincter in Male Patients with Spina Bifida: Comparison of Perioperative and Functional Outcomes between Bulbar Urethra and Bladder Neck Cuff Placement, J Urol 2018, Khene and al.
  2. Robot-assisted laparoscopic artificial urinary sphincter insertion in men with neurogenic stress urinary incontinence, BJUI 2013, Yates and al
  3. Simultaneous concomitant cystoplasty is associated with earlier rather than icreased artificial urinary sphincter infection, J Urol 2005, Catto and al.
Disclosures
Funding none Clinical Trial No Subjects Human Ethics not Req'd This retrospective study is not a clinical trial. Helsinki Yes Informed Consent Yes